  tech nical data sheet fakra - hf calibration kit full version 59 ck 0 10 - 150 rosenberger hochfrequenztechnik gmbh & co. kg p.o.box 1260 d - 84526 tittmoning germany www.rosenberger.de tel. : +49 8 684 18 - 0 fax : +49 8684 18 - 499 email : info@rosenberger.de page 1 / 3 dieses dokumen t ist urheberrechtlich geschtzt this document is protected by copyright rosenberger hochfrequenztechnik gmbh & co. kg rf_35/05.10/6.1 contents device part number quantity calibration option a open circuit plug 0 3 s12l - 00 f s3 1 fc open circuit jack 03 k12l - 00 f s3 1 fc short circuit plug 03 s12s - 00 f s3 1 fc short circuit jack 03 k12s - 00 f s3 1 fc calibration load plug 03 s150 - f 10s3 1 fc cal ibration load jack 03 k150 - f 10s3 1 fc calibration adaptor rpc - 3.50 jack / fakra C 03k159 - s20s3 1 fc calibration adaptor rpc - 3.50 jack / fakra C 03k159 - k 20s3 1 fc calibration adaptor rpc - 3.50 plug / fakra C 03s159 - s20s3 1 fc calibratio n adaptor rpc - 3.50 plug / fakra C 03s159 - k 20s3 1 fc combi w rench 0 3w0 08 - 000 1 - torque wrench 0 3 w0 21 - 000 1 fc plastic housing plug 59z014 - 000z 1 0 - plastic housing jack 59z013 - 000z 10 - a. see declaration of calibration options for explanation.
tech nical data sheet fakra - hf calibration kit full version 59 ck 0 10 - 150 rosenberger hochfrequenztechnik gmbh & co. kg p.o.box 1260 d - 84526 tittmoning germany www.rosenberger.de tel. : +49 8 684 18 - 0 fax : +49 8684 18 - 499 email : info@rosenberger.de page 2 / 3 dieses dokumen t ist urheberrechtlich geschtzt this document is protected by copyright rosenberger hochfrequenztechnik gmbh & co. kg rf_35/05.10/6.1 documentation this kit is delivered with ? usb - stick standard definitions as data files for vector network anaylzer families pna (keysight/agilent) and zva (rohde&schwarz). calibration certificate as pdf - file. ? standard definitions cards printed standar d definitions that can be used on nearly all vector network analyzers. ? kit info card handling precautions and information for installing standard definitions on a vector network analyzer. ? calibration certificate details see declaration of calibration opti ons ? operating manual electrical specifications this specification covers electrical key values for the main calibration standards of the c alibration k it. specific datasheets are available for each component among the part number. calibration standar d frequency parameter specification opens b (plug and jack) dc > 1 ghz > 3 ghz t o to to ? ? ? ? ? ? ? ? shorts b (plug and jack) dc > 1 ghz > 3 ghz t o to to ? ? ? ? ? ? ? ? calibration loads (plug and jack) dc > 1 ghz > 3 ghz t o to to ? ? ? ? ? ? calibration adap t ors rpc - 3.50 to fakra - hf (plug/plug ; plug/jack ; jack/plug ; jack/jack) dc > 1 g hz > 3 ghz t o to to ? ? ? ? ? ? b. the specifications for opens and shorts are given as allowed deviation from nominal model as defined in calibration certificate included with your kit.
tech nical data sheet fakra - hf calibration kit full version 59 ck 0 10 - 150 rosenberger hochfrequenztechnik gmbh & co. kg p.o.box 1260 d - 84526 tittmoning germany www.rosenberger.de tel. : +49 8 684 18 - 0 fax : +49 8684 18 - 499 email : info@rosenberger.de page 3 / 3 dieses dokumen t ist urheberrechtlich geschtzt this document is protected by copyright rosenberger hochfrequenztechnik gmbh & co. kg rf_35/05.10/6.1 declaration of cal ibration options factory calibration standard delivery for this kit includes a factory calibration. the calibration certificate issued reports individual calibration results, traceable to rosenberger standards , national / international standards are not av ailable. model based standard definitions of the calibration standards are reported in agilent/keysight, rohde & schwarz and anritsu compatible vna format. accredited calibration not available. for further, more detailed information see application note an001 on the rosenberger homepage. calibration interval recommendation 12 months recommended accessories - rosenberger test port adaptor - rosenberger vna test cable kit and microwave cable assemblies for further, more detailed information p lease visit our homepage www.rosenberger.com . draft date approved date rev. engineering change number name date h. babinger 02.06.16 martin moder 14 . 1 0.16 a 0 2 16 - 1617 a . youmsi mou 14 . 1 0.16 while the information has been carefully compiled to the best of our knowledge, nothing is intended as represe ntation or warranty on our part and no statement herein shall be construed as recommendation to infringe existing patents. in the effort to improve our products, we reserve the right to make changes judged to be necessary.


▲Up To Search▲   

 
Price & Availability of 59CK010-150

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X